Point LED Red Steady Burn Beacon

120V, Marine Treated

Varenr:
PFB-37001-R-1-C-MT
PFB-37001-R-1-C-MT Point Lighting Corporation PFB37001R1CMT Point LED Red Steady Burn Beacon 120V, Marine Treated
PFB-37001-R-1-C-MT Point Lighting Corporation PFB37001R1CMT Point LED Red Steady Burn Beacon 120V, Marine Treated
Lenker: | DataSheet
PFB-37001-R-1-C-MT   
LED ICAO Red ICAO Medium Intensity Type C (steady-burning) and UK CAP 168 Medium Intensity Obstacle Beacon
 
The PFB LED red ICAO Medium Intensity Type C (steady-burning) and UK CAP 168 Medium Intensity Obstacle. All castings are aluminum, all hardware is stainless steel and the lens is glass. There is no plastic. All exterior metal beacon parts are powdercoat painted aviation yellow for corrosion resistance that meets the US Military Standard Salt Fog Test conducted per MIL-STD-81 OF, Method 509.4, Procedure I.
 
FEATURES
* Flasher failure alarm; beacon remains ON
* LED array failure alarm
* Over voltage & over current protection
* Short circuit & open circuit protection
* Metal oxide varistor surge protection
* No external plastic parts
* Modular components for servicing _ABS
* Replaceable LED array sections (5)
 
Intensity: 2,000 candelas as defined in FAA Advisory Circular 150/5345-43G
Wattage: 67.0 watts AC; 79.6 watts at 1 2V DC; 56.3 watts at 24V DC
Volt-Amps: 110.4 VA at 120V AC
Input Range: 93 to 144 volts 120V AC; 176 to 264 volts 220V AC; 10.8 to 13.2 volts 12V DC; 21.6 to 26.4 volts 24V DC
Temp Rating: ± 55° C per FAA certification test
Dimensions: 15 (381) x 15 (381) x 12 (304) H - Inches (mm)
Weight: 41 1 b 18.6 kg
Mounting: 4 Holes on 13.25-inch circle
 
The basic PFB-37001 beacon (PATENT PENDING) catalog number is intended for use with a Point POC Controller for most applications. Other configuration options below are available to be factory installed
at time of order. Add the separate FAA Photoelectric Controller to all systems. Add the separate SPU Surge Protector Unit or POC Controller as required by the system.
 
UNIVERSAL OPTIONS:
 
MT: The fixture is treated for marine conditions by cleaning per US MIL method III of TT-C-490, chromate priming per US MIL-C-5541, epoxy powder base coat and glossy polyester powdercoat finish coat in
color RAIL 6003 (FED-STD-595 color #14097) green. Oven cured per US MIL-PRF-2471 2A.
 
GPS: Control unit & antenna for Cr5 synchronization of flashing multiple beacons.
 
BACKUP OPTIONS:
 
SB: Standby Beacon: add this option to the 2 beacon to operate upon failure of the primary beacon. This standby beacon &the primary beacon will be stacked and interconnected.
 
ICAO OPTIONS:
 
The basic beacon is FAA L-864 style. Specifically, failure of any FAA LED array results in all arrays turning OFF; partial failure results in no light output. The options below are ICAO (international)
versions; if one array fails, an alarm is generated and the beacon remains ON.
 
B: ICAO Medium Intensity Type B (flashing)
 
C: ICAO Medium Intensity Type C (steady-burning) and UK CAP 168 Medium Intensity Obstacle
 
D: UK CAP 168 Low Intensity (Group B) (steady-burning) Table 6A.1 & CAP 437 paragraph 4.4
 
ALARM CONFIGURATION OPTIONS:
 
K: Required on each beacon when installed with any POC-68001 series digital controller.
The options below are required when the beacon is installed without a POC controller. One of the SA options is required for a single beacon installed without a controller.
The MA options are required for two or more synchronized beacons installed without a controller. For more than four (4) beacons, a POC controller is required.
 
SA1: Single beacon with internal flasher & non-isolated alarm line powered by the line voltage
 
SA2: Single beacon with internal flasher & voltage free alarm line to be powered by a remote AC or DC source supplied by others (isolated alarm line)
 
MA1M: Master beacon to be synchronized with one or more secondary beacons with internal flasher & nonisolated alarm line powered by the line voltage; one master beacon per system.
 
MA1S: Secondary beacon synchronized by the above master beacon with internal flasher & non-isolated alarm line powered by the line voltage; 1 to 3 secondary beacons per system.
 
RECOMMENDED OR REQUIRED ACCESSORIES:
 
SPU: Each beacon contains limited surge protection. All POC controllers include circuit level surge protection. For systems without a POC, an SPU Surge Protector Unit is strongly recommended: SPU-
10770-x x=1 for l2Ov x=2 for 22Ov Separately ordered and separately installed in the line feeding power to the beacons.
 
POC: See file OL300POC for a POC-68001 series system controller with touch screen option.
 
One FAA Photoelectric Controller is required per system. Separately ordered and separately mounted.
PPC
PPC-40002-34T   For AC systems with a POC Controller
PPC-40002-34T-OS For 1 20v systems without a POC; includes override switch
Option —P       For wind turbine applications
 
 
 
 