Ex-XenonStrobe GNExB1 X05 24vDC AMBER

5J 1-2Hz GRP/316 IP66 Ex-db-IIC-Gb-T6

Varenr:
GNExB1X05024AB2A1R.2
GNExB1X05024AB2A1R.2 E2S GNExB1X05024AB2A1R/A Ex-XenonStrobe GNExB1 X05  24vDC AMBER 5J 1-2Hz GRP/316 IP66 Ex-db-IIC-Gb-T6
GNExB1X05024AB2A1R.2 E2S GNExB1X05024AB2A1R/A Ex-XenonStrobe GNExB1 X05  24vDC AMBER 5J 1-2Hz GRP/316 IP66 Ex-db-IIC-Gb-T6 GNExB1X05024AB2A1R.2 E2S GNExB1X05024AB2A1R/A Ex-XenonStrobe GNExB1 X05  24vDC AMBER 5J 1-2Hz GRP/316 IP66 Ex-db-IIC-Gb-T6
GNExB1X05024AB2A1R.2 E2S GNExB1X05024AB2A1R/A Ex-XenonStrobe GNExB1 X05  24vDC AMBER 5J 1-2Hz GRP/316 IP66 Ex-db-IIC-Gb-T6
GNExB1X05024AB2A1R.2 E2S GNExB1X05024AB2A1R/A Ex-XenonStrobe GNExB1 X05  24vDC AMBER 5J 1-2Hz GRP/316 IP66 Ex-db-IIC-Gb-T6 GNExB1X05024AB2A1R.2 E2S GNExB1X05024AB2A1R/A Ex-XenonStrobe GNExB1 X05  24vDC AMBER 5J 1-2Hz GRP/316 IP66 Ex-db-IIC-Gb-T6
Lenker: | Manual | DataSheet | IECEx | DoC | ATEX | GA
Ex Xenon Strobe GNExB1 X05  24vDC with AMBER (orange) lens
 
 
The GNExB1X05 is an IECEx & ATEX approved explosion proof 5 Joule Xenon beacon. The robust IP66 corrosion proof GRP enclosure and extended temperature range ensures the GNExB1X05 is suitable for all Zone 1, 2, 21 & 22 hazardous location signalling applications.
 
The GNExB1X05 beacon produces over 117cd effective - a high output Xenon strobe flash required for safety signalling. The field replaceable colour filter enhances the strobe and is constructed from UV stable PC. The GRP enclosure features a threaded flame path, dual cable entries and a large termination area - all of which significantly reduce installation time.
 
Features:
 
 • Robust, corrosion proof GRP (glass reinforced polyester) enclosure
 • Ingress protection IP66
 • Automatic synchronisation on multi-beacon systems
 • DC voltage versions feature a choice of three flash rates
 • DC voltage units feature remote initiation of flash rate
 • User replaceable Xenon tube mechanically secured against shock & vibration
 • Glass lens & Stainless Steel guard
 • Field replaceable colour filter (easaly change the lens colour)
 • UV stable PC field replaceable lens colour filter
 • Stainless steel fixings
 • Dual cable entries
 • Duplicate cable terminations (in & out for daisy-chain installations)
 
Approvals:
 
 • IECEx UL 15.0003X
   IEC 60079-0 : 2 011
   IEC 60079-1 : 2 014
   IEC 60079-31 : 2 013

 • ATEX DEMKO 15ATEX1448X
   EN 60079-0 : 2 012
   EN 60079-1 : 2 014
   EN 60079-31 : 2 014

Coding:

 • II 2 G Ex db IIC G b T6 Ta -50°C to +40°C
 • II 2 G Ex db IIC G b T5 Ta -50°C to +55°C
 • II 2 G Ex db IIC G b T4 Ta -50°C to +70°C
 • II 2 D Ex tb IIIC Db T110°C Ta -50°C to +70°C
 
Specification:
 
Energy:5 Joules (5Ws)
Flash rate:DC voltages: 1Hz (60fpm), 1.5Hz (90fpm) & double flash
AC voltages: 1Hz (60fpm)
  
Peak Candela:500,000 cd - calculated from energy (J)
Effective Intensity cd:250 cd - calculated from energy (J)
Peak Candela:45,449 cd - measured ref to I.E.S
Effective Intensity cd:117.93 cd - measured ref to I.E.S
  
Lens colours:Red, Amber, Yellow, Green, Blue, Clear & Magenta, 
Voltages DC: 12vDC; 24vDC; 48vDC
Voltages AC: 115vAC; 230vAC
Ingress protection:IP66
  
Enclosure:UV stable GRP (glass reinforced polyester)
Colour:Natural Red - can be provided in alternative colours
Cable entries: 2 x M20 ISO (1 stopping plug inc.)
   Adaptors to M25, 1/2" & 3/4" NPT can be specified
Terminals:0.5 to 2.5mm²
  
Temp. range:-50° to +70°C (-58°F to +158°F)
Tube life:Emissions are reduced to 70% after 8 million flashes
Weight: 1.5kg / 3.3lbs
 
 *All candela data is representative of performance with clear lens at optimum voltage.
 
 
Part Codes:
 
(The actual choices for this particular model are highlighted in red)

 
Version:Part code:
             
Product type:GNExB1

  

Type:X05Xenon Beacon - 5 Joule

    

Voltage: [u]01210-14vDC
02420-28vDC
04842-54vDC
115110-125vAC
230220-240vAC

    

Cable Entry Type: [e]A2 x M20 x 1.5mm
B2 x 1/2" NPT - adaptors
C2 x 3/4" NPT - adaptors
D2 x M25 x 1.5mm - adaptors
E1 x 1/2" NPT - adaptor
F1 x 3/4" NPT - adapator
G1 x M25 x 1.5mm - adaptor

   

Adaptor/StoppingBBrass
plug material: [m]NNickel Plated
SStainless Steel

   

Guard material: [s]1A2 304 Stainless Steel
2A4 316 Stainless Steel

                 

Product version: [v]A1IECEx & ATEX

   

Enclosure colour: [x]RRed
SSpecial - contact E2S for
alternative enclosure colours

   

Lens colour: .[y] 1Red
2A  Amber (Orange)
3Y  Yellow
4Green
5B  Blue
7Clear (Transparent)
8Magenta
 

Example part code:GNExB1 X05 [u] [e] [m] [s] [v] [x] . [y]
Makes this part code :GNExB1 X05 024 A B 2 A1 R .2
 
Explanation of above
Product type:"GNExB1"
Type:"X05" = 5 Joule Xenon Strobe Beacon
Voltage: [u]"024" = 20-28vDC
Cable Entry: [e]"A" = 2 x M20 entries
Stopping plug[m]"B" = Brass stopping plug
Guard material: [s]"2" = A4 316 Stainless Steel Guard
Product version: [v]"A1" = IECEx & ATEX certified
Enclosure colour: [x]"R" = Red Enclosure colour
Lens colour: .[y] ."2" = (A) Amber Lens colour
 

Effective Candela lens colour factor:
 
RedAmber Yellow GreenBlueClear
0.150.510.860.490.121.00
 
 
Current Consumption:
 
Version:Voltage:Current:
12vDC10-14vDC 437mA
24vDC20-28vDC 254mA
48vDC 42-54vDC158mA
115vAC50/60Hz110-125vAC95mA
230vAC50/60Hz220-240vAC54mA
 
 

Assemblies:
 
The GNExB1X05 is available as a plated assembly configured with up to 4 xenon strobe beacons with or without a GNExJ2 Ex d junction box. Contact us for further information.

 