Kockum Sonics TYFON KTV 75/400 complete with solenoid TV88 24vDC
 
General Information
  • Light. rigid and powerful signalling apparatus for different applications e.g. aboard ships, in industry, for military applications and for heavy vehicles etc.
  • Material: Plastic resin of high impact and vibration strength, certain parts glass-fibre reinforced.
  • Entirely maintenance-free. The diaphragm never wears out.
  • Sound intensity can be adjusted by a choke screw and a sordine.
Technical Data

Frequency: Basic note 400 Hz. completed by power and noise penetrating harmonics.
Sound level: At normal adjustment setting. approx. 5 lit/sec.
136 dB(A) at 1 m
120 dB(A) at 6 m
Can be reduced 15 dB with a choke screw if required.
For further reduction. a sordine type TG 5 can be applied.
Working pressure:
In housing (after choke screw): 0.2-0.5 MPa*
In inlet:                                                         0.2-1.2 MPa*
* overpressure
 
Note: When supply pressure is more than 0.7 MPa. the choke must be adjusted so as to attain a clear tone without straining the apparatus.
 
(1 MPa = 10 Bar)

Weight: TYFON only - 0.34 kg
 
 
Solenoid Valve TV88
Standard voltage for Solenoid Valve TV 88: DC: 24V 115V. 230V AC: 115V 230V
 
The valve is delivered with filter and complete fittings for plastic tubing on the outlet side and for copper piping with O.D. 8mm on the inlet side. The valve should not be placed outdoors without protective cover.
 
The short connection between valve and signal apparatus should preferably be of flexible material. (Rubber hose or plastic tubing). For distinct code signals. the pipe line must not be longer than 6m between TYFON and Valve.
 
TYFON KT 75/400 can also be driven by halogencompound gas particularly together with fire extinguishing plants.
 
Note: Blow the pipe line thoroughly clean with compressed air before connecting to signal apparatus or valve.